| Polar Bear PART NO. |
DESCRIPTION |

TO 5075 |
Halogen Leak Detector, model XL-1 (all halogenated refrigerants)
- Microprocessor controlled circuit monitors the sensing tip up to 2000 times per second
- 3VDC, 2 C cell alkaline batteries included
- 14" stainless steel probe with Teflon liner
- Sensitivity levels = 1
- Visual leak indication levels = n/a
|

TO 5078 |
Halogen Leak Detector, model RX-1 (all halogenated refrigerants)
- Microprocessor controlled circuit monitors the sensing tip up to 2000 times per second
- 3VDC, 2 C cell alkaline batteries included
- 14" stainless steel probe with Teflon liner
- Sensitivity levels = 2
- Visual leak indication levels = 6 (single color)
|

TO 5077 |
Halogen Leak Detector, model XP-1 (all halogenated refrigerants)
- Microprocessor controlled circuit monitors the sensing tip up to 2000 times per second
- 3VDC, 2 C cell alkaline batteries included
- 14" stainless steel probe with Teflon liner
- Sensitivity levels = 7
- Visual leak indication levels = 18 (tri-color)
|
| Polar Bear PART NO. |
DESCRIPTION |

TO 5079 |
Halogen Leak Detector, model ZX-1 (all halogenated refrigerants)
- 16" flexible stainless probe
- True mechanical pump
- Heated Pentode Sensor technology:
- Refrigertant specific detection
- Elimination of false alarms
- Unaffected by rapid temperature change
|
| Polar Bear PART NO. |
DESCRIPTION |

TO 5080 |
Leak Detector Kit, model ZX-1KIT
Includes:
- Storage Case
- Detector Unit
- 2 replacement sensors
- Spare filter elements
- Remote battery charging base
- 2 battery chargers (110V, 60 HZ, 12VDC)
- 2 battery packs (nickel cadmium, nickel-metal hydride)
|
| Polar Bear PART NO. |
DESCRIPTION |

TO 2800 |
Leak Detector Set
Detects R11, R12, R134A, R22, R123
Includes:
- Storage Case
- Detector Unit
- TO 2807: Alkaline "D" cells
- TO 2808: Heated Diode Sensor
- TO 2809: Tip Filters (x10)
|
| TO 2807 |
Alkaline "D" cells (accessory for TO 2800) |
| TO 2808 |
Heated Diode Sensor (accessory for TO 2800) |
| TO 2809 |
Tip Filters (x10); (accessory for TO 2800) |
| Polar Bear PART NO. |
DESCRIPTION |

TO 5750 |
Automatic Leak Detector, model 5750A
- Detects R12, R134a
- Super Scanner Pump-style
|
| TO 0545 |
Maintenance Kit (3 tips and 3 protectors for TO 5750) |
| Polar Bear PART NO. |
DESCRIPTION |

TO 6000 |
Halogen HFC/ CFC / HCFC Leak Detector, model H10A
- Detects R12, R134a
- A/C Pump-style
- 115 Volts AC (230 and 240-volts also available)
- 48" Probe cord
|
| TO 0555 |
Maintenance Kit (accessory for TO 6000) |
| Polar Bear PART NO. |
DESCRIPTION |

TO 0790 |
Electronic Leak Detector
- Detects R12, R134a
- 18" Flexible Probe
- Visual Indicator
- Alarm
- Touch-key operation (keypads)
- 10 Different Sensitivity Ranges
- Low Battery Indicator
- Automatic Power-off after 15 minutes
|
| TO 0135 |
Maintenance Kit (2 plastic tip covers & 2 Ion Pump Sensors for TO 0790) |
| TO 0131 |
Ion Pump Sensor (replacement part for TO 0790) |
| TO 0132 |
Aluminum Sensor Housing (replacement part for TO 0790) |
| TO 0187 |
Water Vapor Filter (replacement part for TO 0790) |
| TO 1627 |
Housing (replacement part for TO 0790) |
| Polar Bear PART NO. |
DESCRIPTION |

TO 0791 |
Electronic Leak Detector
- Detects R12, R134a
- 3 position slide switch
- Audible alarm
- LED provided (blinking rate is proportional to leak size)
- Requires 4 AA alkaline batteries
- 18" flexible probe
|
| TO 0135 |
Maintenance Kit (2 plastic tip covers & 2 Ion Pump Sensors for TO 0791) |
| TO 0131 |
Ion Pump Sensor (replacement part for TO 0791) |
| TO 0132 |
Aluminum Sensor Housing (replacement part for TO 0791) |
| TO 0187 |
Water Vapor Filter (replacement part for TO 0791) |
| Polar Bear PART NO. |
DESCRIPTION |

TO 6001 |
Yokogawa Electronic Leak Detector
- For use in USA
- Detects R12, R134a
- Pro Model
- Manually adjust to zero balance control or automatically auto zero to block out background refrigerant levels
- Uses positive ion emission heated diode
- Rechargable internal battery (AC or 12V DC powered)
- Alarm and visual warning light
|

TO 6002 |
Yokogawa Electronic Leak Detector
- For use in U.K.
- Detects R12, R134a
- Pro Model
- Manually adjust to zero balance control or automatically auto zero to block out background refrigerant levels
- Uses positive ion emission heated diode
- Rechargable internal battery (240V AC or 12V DC powered)
- Alarm and visual warning light
|

TO 6003 |
Yokogawa Electronic Leak Detector
- For use in Europe
- Detects R12, R134a
- Pro Model
- Manually adjust to zero balance control or automatically auto zero to block out background refrigerant levels
- Uses positive ion emission heated diode
- Rechargable internal battery (220/230V AC or 12V DC powered)
- Alarm and visual warning light
|
| TO 6007 |
14" Bendable Probe Extension |
| TO 6008 |
Clear Probe Tip for TO 6001, TO 6002, and TO 6003 |
| TO 6009 |
Rubber Probe Tip for TO 6001, TO 6002, and TO 6003 |
| TO 6010 |
Replacement sensor for TO 6001, TO 6002, and TO 6003 |
| TO 6011 |
Leak Reference Bottle |
| TO 6012 |
Tune up kit
Includes:
- 1 - Replacement Sensor (TO 6010)
- 1 - Leak Reference Bottle (TO 6011)
- 3 - Rubber Probe Tips (TO 6009)
- 3 - Flow Balls
- 100 - Filters
|
| Polar Bear PART NO. |
DESCRIPTION |

TO 6004 |
Yokogawa Electronic Leak Detector
- For use in USA
- Detects R12, R134a
- First Model
- Switch Position (PER YEAR):
- SMALL .5oz.(R134A), .1oz.(R12)
- MEDIUM 1oz(R134A), .5oz.(R12)
- LARGE 5oz(R134A), 3oz.(R12)
|

TO 6005 |
Yokogawa Electronic Leak Detector
- For use in EUROPE
- Detects R12, R134a
- First Model
- Switch Position (PER YEAR):
- SMALL .5oz.(R134A), .1oz.(R12)
- MEDIUM 1oz(R134A), .5oz.(R12)
- LARGE 5oz(R134A), 3oz.(R12)
|

TO 6006 |
Yokogawa Electronic Leak Detector
- For use in UK
- Detects R12, R134a
- First Model
- Switch Position (PER YEAR):
- SMALL .5oz.(R134A), .1oz.(R12)
- MEDIUM 1oz(R134A), .5oz.(R12)
- LARGE 5oz(R134A), 3oz.(R12)
|
| TO 6007 |
14" Bendable Probe Extension |
| TO 6008 |
Clear Probe Tip for TO 6004, TO 6005, and TO 6006 |
| TO 6009 |
Rubber Probe Tip for TO 6004, TO 6005, and TO 6006 |
| TO 6010 |
Replacement sensor for TO 6004, TO 6005, and TO 6006 |
| TO 6011 |
Leak Reference Bottle |
| TO 6012 |
Tune up kit
Includes:
- 1 - Replacement Sensor (TO 6010)
- 1 - Leak Reference Bottle (TO 6011)
- 3 - Rubber Probe Tips (TO 6009)
- 3 - Flow Balls
- 100 - Filters
|